Description
PRODUCT SPECIFICATIONS
| Parameter | Specification |
|---|---|
| Working Temperature | -30°C to +40°C |
| Storage Temperature | -40°C to +70°C |
| Relative Humidity | 5% to 95% |
| Heat Dissipation Mode | Fan Cooling |
| Input Voltage | 180–260 VAC |
| Input Frequency | 50 Hz / 60 Hz |
| Battery Chemistry | LiFePO₄ |
| DC Output | 14.2 V / 50 A |
| Ring Connector Size | M10 (fits M8 with washer) |
HOW TO CONNECT YOUR CHARGER
-
Remove the charger from its packaging and keep the packaging for future storage or transport.
-
Check that the air vents are clear and unobstructed.
-
Attach the black (negative -) cable to the black (negative -) battery terminal.
-
Attach the red (positive +) cable to the red (positive +) battery terminal.
-
Tighten the terminal rings securely.
-
Plug the charger into the mains and switch it ON.
-
Confirm that the indicator light flashes green — this means the charger is in the pre-charge inspection stage.
HEALTH AND SAFETY INSTRUCTIONS
-
Do not disassemble or open the charger.
-
Do not leave the charger operating unattended.
-
Keep air vents clear at all times.
-
Keep the charger away from heat sources and water.
-
Do not crush, incinerate, or modify the charger.
-
Use the charger only within the manufacturer’s specified parameters.